Lactate and Ventilatory Thresholds Explained
A threshold is a point in an exercise test where the body changes gear. The first marks the top of the intensity that can be held in a steady state on fat and carbohydrate together; the second marks the top of the intensity at which lactate and oxygen uptake can stabilise at all. Training zones exist to approximate those two points, and a cardiopulmonary exercise test finds them from breathing alone, without a blood sample, while a lactate step test finds them from finger-prick blood. This page carries a modelled sample test that can be set to an athlete's maximal oxygen uptake, body mass, heart rate and threshold profile, drawn three ways, as the V-slope, the ventilatory equivalents and the lactate curve, with the three intensity domains, the heart rates and work rates that bound them, the methods that place thresholds and what each answers, and the conditions a real test must hold still. It is a teaching tool; the one thing it cannot do is find a threshold that is not already set, which is what the test is for. Beneath it sit four figures from the APEX Knowledge Hub: the V-slope method, lactate over a constant effort, the power–duration curve, and the three determinants of endurance performance.
Two thresholds, three domains
Below the first threshold, oxygen uptake and blood lactate reach a steady state within a few minutes and fat supplies most of the energy. Between the first and second, lactate is elevated but steady, and oxygen uptake drifts upward over minutes through the slow component. Above the second, in the severe domain, neither stabilises: lactate climbs, oxygen uptake rises to its maximum, and exhaustion follows. Maximal lactate steady state is the highest intensity at which blood lactate stays constant though elevated, typically near 4 mmol/L and highly individual; above it, lactate rises by more than 1 mmol/L over the final 20 to 30 minutes of constant work. Critical power, the asymptote of the power–duration relationship, sits at the same boundary between the heavy and severe domains, the highest power at which oxygen uptake and blood lactate can reach a steady state, and Poole and colleagues' 2016 review summarised the evidence that it is a physiological threshold rather than a mathematical convenience. Zones identify these states. Heart rate is used because it is easy to measure continuously, but the thresholds occur at different percentages of maximum in different people and shift with training: an athlete whose threshold moves from 78 to 84% of maximum over a training block has changed physiologically while percentage-based zone boundaries have not moved. The sample test shows the three domains with the heart rates and work rates that bound them for the settings chosen.
References
- Poole, D.C. et al. (2016) ‘Critical power: an important fatigue threshold in exercise physiology’. PubMed
- Jones, A.M. et al. (2010) ‘Critical power: implications for determination of V̇O₂max and exercise tolerance’. PubMed
- Seiler, K.S. and Kjerland, G.Ø. (2006) ‘Quantifying training intensity distribution in elite endurance athletes: is there evidence for an “optimal” distribution?’, Scandinavian Journal of Medicine & Science in Sports, 16(1), pp. 49–56. doi:10.1111/j.1600-0838.2004.00418.x · PubMed
Finding them from breathing
Beaver, Wasserman and Whipp's 1986 V-slope method identifies the first ventilatory threshold as the point where carbon dioxide output begins to rise faster than oxygen uptake, the bicarbonate buffering of lactate adding carbon dioxide to the expired air. The second threshold appears where ventilation accelerates relative to carbon dioxide output as the buffering is overwhelmed and pH falls. The ventilatory equivalents, ventilation divided by oxygen uptake and by carbon dioxide output, and the end-tidal gas pressures provide corroborating markers: the equivalent for oxygen rises at the first threshold while the equivalent for carbon dioxide stays flat, and both rise at the second. Agreement with lactate thresholds is good at the group level and variable within individuals, and ventilatory thresholds are typically identified 10 to 30 seconds earlier in a ramp test. Software placement of the breakpoints depends on smoothing and on the section of the test analysed, which is why the analyst's chosen window should be recorded with the result, and breath-by-breath noise, irregular breathing and short ramps degrade the breakpoints; results from different ramp rates should not be pooled. The sample test moves its breakpoints with the ramp rate for that reason.
References
Finding them from blood
A step test produces a lactate curve, and where the threshold sits on it depends on the method. Fixed concentrations of 2 and 4 mmol/L are simple but ignore individual baselines. The first rise above baseline, LT1, at baseline plus 0.5 to 1.0 mmol/L, marks the upper limit of the moderate domain. Dmax places the threshold at the point of maximal distance between the curve and the line joining its ends; the modified version starts that line at the first rise, which makes it less sensitive to the resting value. Jamnick and colleagues' 2020 examination of intensity-anchoring methods found that thresholds derived by different methods, and the same method with different stage durations, produced meaningfully different exercise intensities and domain boundaries, and Faude, Kindermann and Meyer's 2009 review reached a similar conclusion about the validity of lactate threshold concepts: each is a reasonable estimate of a domain boundary within its own protocol, and none transfers to another protocol without re-testing. A strong mathematical fit does not establish a valid physiological threshold, and step length, warm-up and fuelling all shift the curve, which the sample test shows by moving its lactate thresholds with the stage length. For an athlete the practical rule is to choose one method and one protocol and keep them, because the change between two tests is the useful quantity. Lactate itself is not a waste product: it is a fuel for muscle, heart and brain, a precursor for new glucose in the liver, and a signal, and a rising concentration reflects the balance between production and clearance rather than an oxygen-starved state.
References
What a maximum is, and when a change is real
Currell and Jeukendrup set out the three properties of a test in 2008: validity, reliability and sensitivity, and most testing failures are of the second and third. Classically, maximal oxygen uptake was established by discontinuous protocols that produced an unambiguous plateau; modern ramp protocols do not reliably produce it, and the secondary criteria adopted in its place, a respiratory exchange ratio above a cut-off, a heart rate near the age-predicted maximum, a lactate above a threshold, are met at submaximal effort by some people and unattainable by others. The verification bout described by Rossiter, Kowalchuk and Whipp in 2006 replaces those proxies with a direct check: after recovering from the ramp, the subject performs a constant-load bout above the final ramp stage, and if oxygen uptake rises to the same ceiling and no further, the maximum is confirmed. Poole and Jones adopted it as the standard in 2017 and recommend that a value reported without it be described as a peak. Every measurement also carries noise, which Hopkins formalised as typical error in 2000: a retest can differ from a test by that much with nothing real having changed, so an observed change is evidence of a real change only when it exceeds the test's typical error, and it matters only when it also exceeds the smallest change of practical importance. A two-watt improvement is usually measurement variation, and consumer devices estimating these quantities from wrist data cannot substitute for measurement because their error swallows the changes being tracked.
References
- Currell, K. and Jeukendrup, A.E. (2008) ‘Validity, reliability and sensitivity of measures of sporting performance’, Sports Medicine, 38(4), pp. 297–316. Search PubMed
- Rossiter, H.B., Kowalchuk, J.M. and Whipp, B.J. (2006) ‘A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exercise’, Journal of Applied Physiology, 100(3), pp. 764–770. Search PubMed
- Poole, D.C. and Jones, A.M. (2017) ‘Measurement of the maximum oxygen uptake V̇O2max: V̇O2peak is no longer acceptable’, Journal of Applied Physiology, 122(4), pp. 997–1002. doi:10.1152/japplphysiol.01063.2016 · PubMed
- Hopkins, W.G. (2000) ‘Measures of reliability in sports medicine and science’, Sports Medicine, 30(1), pp. 1–15. Search PubMed
Why heart rate alone is not enough
When Robergs and Landwehr traced the history of 220 minus age in 2002, they found it had emerged from an informal reading of existing data rather than from a study; its error of 7 to 11 beats per minute spans about two training zones. Tanaka, Monahan and Seals' equation, 208 minus 0.7 times age, from 351 studies and cross-validated in 514 people, reduces the systematic error in the average, but two healthy fifty-year-olds can differ by twenty beats in true maximum and no age equation separates them. The sample test accepts a measured maximum for that reason and labels the heart rates it derives from age as inheriting the equation's error. Heart rate at a given workload also moves with heat, dehydration, altitude, caffeine, illness, sleep and fatigue, and drifts upward through prolonged exercise at constant power, so the thresholds are best anchored to the physiological transitions themselves and the heart rates read as the day's expression of them. A maximal oxygen uptake test measures the ceiling and says nothing about the fraction of it an athlete can sustain or the economy with which oxygen becomes speed, the two determinants that keep improving after the maximum has plateaued, which is the argument for measuring all three.
References
- Robergs, R.A. and Landwehr, R. (2002) ‘The surprising history of the "HRmax=220-age" equation’, Journal of Exercise Physiology Online, 5(2), pp. 1–10. Search PubMed
- Tanaka, H., Monahan, K.D. and Seals, D.R. (2001) ‘Age-predicted maximal heart rate revisited’, Journal of the American College of Cardiology, 37(1), pp. 153–156. doi:10.1016/S0735-1097(00)01054-8 · PubMed
- Joyner, M.J. and Coyle, E.F. (2008) ‘Endurance exercise performance: the physiology of champions’, The Journal of Physiology, 586(1), pp. 35–44. doi:10.1113/jphysiol.2007.143834 · PubMed
Limitations
Everything on the page is a model: the breakpoints sit where the profile settings place them, the lactate curve follows a formula, and the response to ramp rate and stage length is illustrative of the direction the literature reports rather than a measured effect. Real tests are noisier, the two threshold families do not coincide exactly, and software and analysts differ in where they place the same breakpoint on the same data. The sample test shows what the measurements look like and what the thresholds mean; it cannot say where an individual's thresholds are, and a result from a test should travel with its protocol, device, ramp rate, stage length and analysis window so that the next test is compared like with like.
Frequently asked questions
What is the difference between VT1 and VT2?
VT1, the first ventilatory threshold, is where carbon dioxide output starts to rise faster than oxygen uptake and marks the top of the moderate domain. VT2, the second, is where ventilation accelerates relative to carbon dioxide output as buffering is overwhelmed, and marks the boundary between the heavy and severe domains, near maximal lactate steady state and critical power.
Is lactate threshold the same as ventilatory threshold?
They mark the same transitions by different signals. Agreement is good at the group level and variable within individuals, and ventilatory thresholds are typically found 10 to 30 seconds earlier in a ramp test.
What lactate value is the threshold?
It depends on the method: the first rise above baseline, a fixed 2 or 4 mmol/L, Dmax, or maximal lactate steady state, which is near 4 mmol/L but individual. Each is valid within its own protocol and none transfers to another without re-testing.
Why do my heart-rate zones not match the test?
Age-predicted maximum heart rate carries an error of 7 to 11 beats, and the thresholds sit at different percentages of maximum in different people and move with training. Zones anchored to measured thresholds track the physiology; percentage zones do not.
What is critical power?
The asymptote of the power–duration curve: the highest power at which oxygen uptake and lactate can reach a steady state, at the boundary between the heavy and severe domains. Three to five all-out efforts of two to fifteen minutes estimate it, with a fixed reserve of work, W′, available above it.
How do I know a VO2max test was really maximal?
A verification bout: a constant-load effort above the final ramp stage after recovery. If oxygen uptake reaches the same ceiling and no further, the maximum is confirmed; without that check the value is a peak.
Related tools
Measure it instead of estimating it
A VO2 max assessment replaces population averages with your own measured values.