Calculators · Training load

Critical Power and W′ Calculator

Critical power is the highest power an athlete can hold while oxygen uptake and blood lactate still settle, and W′ is the fixed amount of work available above it before exhaustion. Together they describe the whole of an athlete's capacity between about two and fifteen minutes with two numbers, and they can be estimated from a handful of maximal efforts without a laboratory. The calculator on this page takes two to five efforts, as duration and mean power for cycling or as time and distance for running, fits the three models used in the research literature, reports critical power or critical speed with W′ or D′ and their standard errors, selects the best-constrained model, and uses it to draw the power–duration curve, to predict time to exhaustion at any target, and to follow W′ through an interval session. Beneath it sit three figures from the APEX Knowledge Hub: the power–duration hyperbola, the typical error of a test, and oxygen uptake kinetics after a step in work rate.

What critical power is

Across efforts lasting from about two to fifteen minutes, the power an athlete can sustain falls hyperbolically with time. The asymptote of that curve is critical power, and the curvature constant, W′, is a fixed amount of work that can be performed above critical power however it is spent: a little for a long time or a lot for a short one. Poole and colleagues' 2016 review placed critical power at the boundary between the heavy and severe intensity domains, the highest power at which oxygen uptake and blood lactate can reach a steady state, and summarised the evidence that it is a physiological threshold rather than a mathematical convenience. Above it, the oxygen uptake slow component continues to rise despite a constant work rate until oxygen uptake reaches its maximum, and exhaustion follows soon afterwards; Jones and Poole's 2005 introduction to oxygen uptake kinetics describes that sequence for work rates above critical power. Critical power is not a power that can be held indefinitely. Below it the hyperbola sets no time limit, and in practice fuel, heat and other fatigue processes decide how long the effort lasts. For running the same relationship holds as critical speed and D′, with distance in place of work.

References

  1. Poole, D.C. et al. (2016) ‘Critical power: an important fatigue threshold in exercise physiology’. PubMed
  2. Jones, A.M. and Poole, D.C. (2005) ‘Oxygen uptake dynamics: from muscle to mouth—an introduction to the symposium’, Medicine and Science in Sports and Exercise, 37(9), pp. 1542–1550. doi:10.1249/01.mss.0000177466.01232.7e · Search PubMed
  3. Jones, A.M. et al. (2010) ‘Critical power: implications for determination of V̇O₂max and exercise tolerance’. PubMed

Testing for it

The parameters are estimated from maximal efforts of different durations. Jones and colleagues showed in 2010 that critical power and W′ derived from three to five maximal efforts predict time to exhaustion in the severe domain with an error in the region of 5 to 10%. Meyler and colleagues' 2023 study at the University of Hertfordshire illustrates the laboratory version: constant work-rate trials ridden to task failure, each intended to last between two and fifteen minutes, two per day separated by an hour of recovery, with the shortest trials lasting 196 ± 36 s and the longest 796 ± 167 s, and the highest oxygen uptake in each trial checked against the athlete's maximum. The estimate is only as good as the efforts that feed it. A submaximal trial, a badly paced one or a change of conditions between trials lowers one point on the curve and moves both parameters, which is why the calculator flags an effort that is as fast as or faster than a shorter one and why a weak effort should be repeated rather than kept. Efforts shorter than two minutes and longer than about twenty minutes break the hyperbolic assumption, so the window of two to fifteen minutes is shaded on the chart and efforts outside it are flagged.

References

  1. Jones, A.M. et al. (2010) ‘Critical power: implications for determination of V̇O₂max and exercise tolerance’. PubMed
  2. Meyler, S., Bottoms, L., Wellsted, D. and Muniz-Pumares, D. (2023) ‘Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake’, Experimental Physiology, 108(4), pp. 581–594. doi:10.1113/EP090878 · Search PubMed

Three models and their standard errors

The same efforts can be fitted three ways, and the calculator reports all of them. The work–time model regresses total work on duration, so that work equals W′ plus critical power multiplied by time; the power–1/time model regresses power on the reciprocal of duration, so that power equals critical power plus W′ divided by time; and the hyperbolic model fits time as W′ divided by the power above critical power directly. Meyler and colleagues fitted all three for each participant, calculated the standard error of the estimate for critical power and for W′ under each, and used the model with the lowest combined standard error for that individual, an approach they attribute to Black and colleagues. In their ten participants the work–time model was selected for nine, with fits of r² = 0.99, and the 1/time model for one. The calculator follows the same rule and highlights the selected model. The standard errors deserve attention in their own right. With three efforts they rest on a single degree of freedom and are themselves uncertain; with two efforts there is no error term at all, because two points define the line exactly. A standard error above about 5% for critical power or 10% for W′ is the signal to repeat the weakest effort or add one at a different duration. The same logic applies between tests: Hopkins' 2000 account of typical error, and Currell and Jeukendrup's 2008 review of validity, reliability and sensitivity, make the point that a change smaller than the test's own noise is not evidence of a change, and the second figure under the calculator lets that be seen directly.

References

  1. Meyler, S., Bottoms, L., Wellsted, D. and Muniz-Pumares, D. (2023) ‘Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake’, Experimental Physiology, 108(4), pp. 581–594. doi:10.1113/EP090878 · Search PubMed
  2. Hopkins, W.G. (2000) ‘Measures of reliability in sports medicine and science’, Sports Medicine, 30(1), pp. 1–15. Search PubMed
  3. Currell, K. and Jeukendrup, A.E. (2008) ‘Validity, reliability and sensitivity of measures of sporting performance’, Sports Medicine, 38(4), pp. 297–316. Search PubMed

What the estimate predicts

Above critical power, time to exhaustion equals W′ divided by the excess power, so a rider with a critical power of 280 W and a W′ of 20 kJ is predicted to last about eight minutes at 320 W and about three minutes at 390 W, and the calculator's target slider moves that point along the curve. The practical value of the two numbers lies in prescription. Meyler and colleagues compared exercise set relative to physiological thresholds with exercise set as a percentage of maximal oxygen uptake in the same people. Twenty minutes at 75% of maximal oxygen uptake placed the work rate above critical power in seven of ten participants and only three completed it, whereas every participant completed twenty minutes set midway between the gas exchange threshold and critical power. Five three-minute intervals at 110% of critical power with three minutes of recovery at 20 W were completed by all ten, while five at 85% of maximal oxygen uptake were completed by two, and the share of W′ spent at the end of the session, or at task failure, was 30 ± 12% in the first case and 73 ± 22% in the second. Critical power fell at 69 ± 6% of maximal oxygen uptake and the gas exchange threshold at 67 ± 12% of critical power, so the same percentage anchor landed in different domains for different people. The calculator's W′ balance panel reproduces the model they used, in which W′ is spent at the rate of power minus critical power during work and recovers exponentially during recovery, with a time constant of 546 × e^(−0.01 × DCP) + 316 seconds where DCP is the difference between critical power and the recovery power; the default session is their protocol, and the panel reports how much of W′ is spent per interval and at the end, and the interval in which it would run out.

References

  1. Jones, A.M. et al. (2010) ‘Critical power: implications for determination of V̇O₂max and exercise tolerance’. PubMed
  2. Meyler, S., Bottoms, L., Wellsted, D. and Muniz-Pumares, D. (2023) ‘Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake’, Experimental Physiology, 108(4), pp. 581–594. doi:10.1113/EP090878 · Search PubMed

Critical speed for runners

Runners enter time and distance instead of duration and power, and the calculator returns critical speed as a pace per kilometre with D′, the distance available above it, in metres. The relationship is the same hyperbola and the same three models apply, with distance standing in for work. Two efforts give a usable critical speed for setting training zones but a poorly constrained D′, and a 5 km and a 10 km best effort are the common two-point example; three to five efforts between two and fifteen minutes, on the same surface in similar conditions, constrain both. Because the time constant for W′ recovery was derived for cycling power, the W′ balance panel is shown for cycling only.

References

  1. Poole, D.C. et al. (2016) ‘Critical power: an important fatigue threshold in exercise physiology’. PubMed
  2. Jones, A.M. et al. (2010) ‘Critical power: implications for determination of V̇O₂max and exercise tolerance’. PubMed

Limitations

The calculator fits the efforts it is given and cannot tell a maximal effort from a submaximal one except by its position on the curve. Its predictions apply between two and fifteen minutes and are not extended beyond twenty; a marathon, a century or a time trial of an hour are governed by fuel, heat and durability that the two-parameter model does not contain. Critical power and functional threshold power are separate quantities estimated by different procedures and are not interchangeable. The W′ balance model is a research tool whose recovery time constant was derived from cycling studies and carries considerable individual variation, and the standard errors reported from three efforts are themselves imprecise. An estimate should travel with the efforts that produced it, their dates, conditions and equipment, so that the next one is compared like with like.

Frequently asked questions

What is critical power?

The asymptote of the power–duration curve: the highest power at which oxygen uptake and blood lactate can reach a steady state, at the boundary between the heavy and severe domains. Above it a fixed reserve of work, W′, is available before exhaustion.

How many efforts do I need?

Three to five maximal efforts of two to fifteen minutes at different durations. Two efforts give an estimate with no error term; the calculator reports standard errors from three or more.

Is critical power the same as FTP?

No. They are separate quantities estimated by different procedures and are not interchangeable, and critical power is not a power that can be held indefinitely.

What is W′?

The curvature constant of the hyperbola: a fixed amount of work, in kilojoules, that can be performed above critical power however it is spent. For runners the equivalent is D′, a distance in metres above critical speed.

How accurate are the predictions?

Critical power and W′ from three to five maximal efforts predict time to exhaustion in the severe domain with an error in the region of 5 to 10%. Predictions beyond twenty minutes are outside the model and are not shown.

Can runners use it?

Yes. Enter time and distance for each effort and the calculator returns critical speed as a pace with D′ in metres; the same models and the same two-to-fifteen-minute window apply.

Related tools

Measure it instead of estimating it

A VO2 max assessment replaces population averages with your own measured values.

Book a test