What does a VO₂max test measure, and what does a watch estimate miss?
Short answer
A maximal cardiopulmonary test measures the highest rate at which the body can take up and use oxygen, from the air breathed in and out at the mouth, and with a verification bout confirms that the value was a maximum rather than a peak. A watch estimates the same quantity from heart rate and pace, and its error is large enough to swallow the changes an athlete is trying to track. A full test also reports the thresholds and economy, which a watch cannot.
What the ceiling is
Maximal oxygen uptake is the integrated capacity of heart, blood, lungs and muscle to deliver and use oxygen. Trained athletes have a larger stroke volume, more blood, and denser capillaries and mitochondria in trained muscle, and most evidence places the limit in oxygen delivery by the heart and circulation rather than its use in muscle, as Bassett and Howley set out in 2000. Champion endurance athletes record 70 to 85 mL/kg/min, about double untrained adults, and within that group the range is narrow. Joyner and Coyle’s 2008 model makes the point that performance depends on three things that multiply: the ceiling, the fraction of it sustainable for the event, and the efficiency with which oxygen becomes speed. The maximum plateaus after the first years of serious training; the other two keep improving, which is why experienced athletes keep getting faster while their laboratory maximum stays put.
What makes a measurement a measurement
Classically, maximal oxygen uptake was established by discontinuous protocols that produced an unambiguous plateau. Modern ramp protocols do not reliably produce it, and the secondary criteria adopted in its place, a respiratory exchange ratio above a cut-off, a heart rate near the age-predicted maximum, a lactate above a threshold, are met at submaximal effort by some people and unattainable by others. The verification bout described by Rossiter, Kowalchuk and Whipp in 2006 replaces those proxies with a direct check: after recovering from the ramp, the subject performs a constant-load bout above the final ramp stage, and if oxygen uptake rises to the same ceiling and no further, the maximum is confirmed. Poole and Jones adopted it as the standard in 2017 and recommend that a value reported without it be described as a peak.
Why the watch number cannot track change
Every measurement carries noise, which Hopkins formalised as typical error: a retest can differ from a test by that much with nothing real having changed, so an observed change is evidence of a real change only when it exceeds the test’s typical error, and it matters only when it also exceeds the smallest change of practical importance. Currell and Jeukendrup’s review of validity, reliability and sensitivity makes the same point for performance tests. Consumer devices estimating these quantities from wrist data cannot substitute for measurement because their error swallows the changes being tracked; week-to-week movement in such a figure is largely its own noise. A full cardiopulmonary test reports the maximum, the first and second thresholds and the oxygen cost of a fixed speed, which are the quantities training zones and race pacing are built on and the ones that keep changing after the maximum has plateaued.
Related pages
References
Sources
- Bassett, D.R. and Howley, E.T. (2000) ‘Limiting factors for maximum oxygen uptake and determinants of endurance performance’, Medicine & Science in Sports & Exercise, 32(1), pp. 70–84. PubMed
- Joyner, M.J. and Coyle, E.F. (2008) ‘Endurance exercise performance: the physiology of champions’, The Journal of Physiology, 586(1), pp. 35–44. doi:10.1113/jphysiol.2007.143834 · PubMed
- Rossiter, H.B., Kowalchuk, J.M. and Whipp, B.J. (2006) ‘A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exercise’, Journal of Applied Physiology, 100(3), pp. 764–770. Search PubMed
- Poole, D.C. and Jones, A.M. (2017) ‘Measurement of the maximum oxygen uptake V̇O2max: V̇O2peak is no longer acceptable’, Journal of Applied Physiology, 122(4), pp. 997–1002. doi:10.1152/japplphysiol.01063.2016 · PubMed
- Hopkins, W.G. (2000) ‘Measures of reliability in sports medicine and science’, Sports Medicine, 30(1), pp. 1–15. Search PubMed
- Currell, K. and Jeukendrup, A.E. (2008) ‘Validity, reliability and sensitivity of measures of sporting performance’, Sports Medicine, 38(4), pp. 297–316. Search PubMed