Questions answered

Is the lactate threshold the same as the anaerobic threshold?

Short answer

They describe the same transitions by different signals. The first threshold marks the top of the intensity that can be held in a steady state on fat and carbohydrate together; the second marks the top of the intensity at which lactate and oxygen uptake can stabilise at all. Ventilatory thresholds find them from breathing, lactate thresholds from finger-prick blood, and the anaerobic threshold is an older umbrella term for the second transition whose name the physiology no longer supports.

Two transitions, three domains

Below the first threshold, oxygen uptake and blood lactate reach a steady state within a few minutes and fat supplies most of the energy. Between the first and second, lactate is elevated but steady and oxygen uptake drifts upward through the slow component. Above the second, in the severe domain, neither stabilises. Maximal lactate steady state, the highest intensity at which blood lactate stays constant though elevated, sits at the second boundary, typically near 4 mmol/L and highly individual, and critical power sits at the same boundary; Poole and colleagues’ 2016 review summarised the evidence that it is a physiological threshold rather than a mathematical convenience. Whichever name is used, the quantity being sought is the boundary of a domain.

Breathing or blood

Beaver, Wasserman and Whipp’s 1986 V-slope method identifies the first ventilatory threshold as the point where carbon dioxide output begins to rise faster than oxygen uptake, the bicarbonate buffering of lactate adding carbon dioxide to the expired air; the second threshold appears where ventilation accelerates relative to carbon dioxide output as the buffering is overwhelmed and pH falls. Lactate methods read the same transitions from a step test: the first rise above baseline, LT1, at baseline plus 0.5 to 1.0 mmol/L; fixed concentrations of 2 and 4 mmol/L; Dmax, the point of maximal distance between the curve and the line joining its ends; and maximal lactate steady state itself. Agreement between the ventilatory and lactate families is good at the group level and variable within individuals, and ventilatory thresholds are typically identified 10 to 30 seconds earlier in a ramp test.

Why the names and the numbers disagree

Jamnick and colleagues’ 2020 examination of intensity-anchoring methods found that thresholds derived by different methods, and the same method with different stage durations, produced meaningfully different exercise intensities and domain boundaries, and Faude, Kindermann and Meyer’s 2009 review reached a similar conclusion about the validity of lactate threshold concepts: each is a reasonable estimate of a domain boundary within its own protocol, and none transfers to another protocol without re-testing. The anaerobic label is the one the physiology has left behind, because the rise in lactate reflects the balance of production and clearance rather than a muscle running without oxygen. For an athlete the practical rule is to choose one method and one protocol and keep them, because the change between two tests is the useful quantity, and a result should travel with its protocol, device, ramp rate, stage length and analysis window.

Related pages

References

Sources

  1. Beaver, W.L., Wasserman, K. and Whipp, B.J. (1986) ‘A new method for detecting anaerobic threshold by gas exchange’. PubMed
  2. Poole, D.C. et al. (2016) ‘Critical power: an important fatigue threshold in exercise physiology’. PubMed
  3. Jamnick, N.A. et al. (2020) ‘An examination and critique of current methods to determine exercise intensity’. PubMed
  4. Faude, O., Kindermann, W. and Meyer, T. (2009) ‘Lactate threshold concepts: how valid are they?’. PubMed
  5. Brooks, G.A., Arevalo, J.A., Osmond, A.D., Leija, R.G., Curl, C.C. and Tovar, A.P. (2022) ‘Lactate in contemporary biology: a phoenix risen’, The Journal of Physiology, 600(5), pp. 1229–1251. doi:10.1113/JP280955. doi:10.1113/JP280955 · PubMed